Equipment Technical Parameters

Technical Performance and Features
• Automatic system control for low-pressure water injection, high-pressure water injection, and pressure holding time;
• Automatic unloading during standby and automatic resumption of operation upon startup, reducing oil temperature, extending equipment life, and saving energy;
• Safety interlock between screw-operated pressure and water pressure unloading;
• Equipped with a safety door to effectively prevent accidents;
• Advanced software system; equipment operation, test result recording, and analysis can all be performed with a single touch on the touchscreen;
• Screw-operated pressure clamping of the flange ensures no external force affects the tested valve;
• Can be configured as a multi-station testing platform to improve work efficiency.